Installation and OperatingInstructionsThis installation manual will help youobtain a safe, efficient, dependableinstallation for your firepla
63.2.4 Accelerated CombustionThe maximum heat output for the BIS ULTRA is achieved by burningwith the combustion air damper opened.By thi
73.2.7 Starting And Maintaining a FireA) Place several crumpled up balls of newspaper in the firebox. Place small dry pieces ofkindling on top of th
8the house or through the outside air duct. When operating the BIS ULTRA, open anearby window temporarily to check adequacy of the rep
93.3 MAINTAINING YOUR BIS ULTRA3.3.1 CreosoteWhen wood is burned slowly, it produces tar and other organic vapours which combinewith expelled m
103.3.4 Doorframe CareUse a glass cleaner and a soft cloth to polish the frame. Do not use abrasives such as steelwool or steel pads for they may scr
11The doors must be installed onlywhen the installation of the BISULTRA is completed. All you haveto do is fit the male part of the hinge,
12household glass cleaners will not clean creosote. Do not use abrasives such as steel pads,steel wool or oven cleaner as they will scratch the glass
133.4.2 Hearth Extension RequirementsThe BIS ULTRA may be installed directly on a combustible floor, however the hearthextension in front o
14 Figure 5 Figure 63.4.3 Framing, Facing and MantelThe construc
Printed in Canada Rev. 9 April 2007PIBISULTRAEPA
15Figure 7Figure 9Figure 8Figure 10
16INSULATED CHASE CONSTRUCTIONFacing1. Combustible wall (such as Gyproc) must be installed flush with the fireplace. It maynot project in front o
17Figure 12Figure 133.5 HOT AIR DUCTING INSTALLATIONDifferent hot air ducting systems can be installed with the BIS ULTRA:- Gravity kit- Forced air
18 NOTE : To install the single hot air outlet, in conjunction with AC chimney,the chimney must be offset towards the back using
19NOTE: both pipes of the double hot air outlet must be installed. Any other installationmay cause fire and void the warranty. Figure 18The duct sy
20Exception #2: For the single outlet, the framing must be 8 _" x 32 _" (210 mm x 820mm) or as required by the integrated spacers
213.6 OUTSIDE AIR KITDuring operation, the fireplace requires air for combustion and draws air out of the house.It may starve other fuel burning appl
22 4. THE CHIMNEY4.1 CHIMNEY INSTALLATION NOTES1. If possible, install an interior chimney, as it will provide better performance. In areaswith co
238. A rain cap must be installed on topof the chimney. Failure to install arain cap may cause corrosionproblems.9. Cut and frame square h
24flashing under the upper shingles and on top of the lower shingles. Nail the flashingto the roof, using roofing nails.6. Place the storm colla
25 YEAR LIMITED WARRANTY• Security Chimneys International Ltd. warrants to the owner of a Security Fireplace that the wood burning fireplace wil
25Figure 28NOTE : THE OUTSIDE AIR KIT ISMANDATORY FOR BOTH FIREPLACEAND CHIMNEY
26Figure 29Figure 30Table 2ROOF DOWN SLOPE HOLE SIZESLOPESecure TempASHT+Nova TempHT6103+Secure TempS-2100+Nova TempHT6000+ACRoof Pitch6"6&quo
274.3 OFFSET CHIMNEY INSTALLATONThe minimum chimney height when using elbows is:Fireplace modelBIS ULTRAChimney modelSecure TempS-2100+ / Nova TempHT6
28N.B. : An AC-SB starter section must be used before installing an elbow. When offset is neededimmediately off the top of the
29ONE LENGTH BETWEEN ELBOWSTWO LENGTHS BETWEEN ELBOWSCHIMNEY6”ELBOWDEVIATION& HEIGHT8”12”18”24”36”48”8” & 48”12” & 48”18” & 48”24” &am
30Figure 31Figure 32
314.4 ANGLED WALL RADIATION SHIELD(RSM+, RSMI30, RSMI45)When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firesto
334.5 CHIMNEY SUPPORT INSTALLATIONUNIVERSAL ROOF SUPPORTThis support has three possible uses:1. For Secure TempASHT+ / Nova TempHT6103+ and Se
344.6 CHIMNEY CHASE AND MULTIPLE TERMINATIONSFor the purpose of this manual, a chimney chase is considered a part of the chimneysystem rathe
Details of The 25 Year LimitedFireplace WarrantyYear 1:Parts and labour (no charge)(see on page for exclusions and conditions)Air control
354.8 INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATIONWARNING: Before starting the installation, the masonry chimney must be inspected bya qualifi
365. PARTS AND COMPONENTS LIST AC Chimney Description Part No. Lengths 6" dia.12" length AC6L1218" length AC6L1836&qu
37Description :Part No.: Complete double ducting system including: 2 elbows 90º, 2 telescopiclengths, 2 grill supports and 2 black grills
38Back refractory PR-SR1972Right side refractory PR-SR1971DLeft side refractory PR-SR1971GBottom refractory PR-SR19731st Secondary air tube (r
iTABLE OF CONTENTS1. SAFETY RULES ... 12. CERTIFICATION
11. SAFETY RULES FOR OPERATING YOURFIREPLACE MODEL BIS ULTRAWarning: An outside air kit must be installed on the fireplace model BIS ULTRAWarning: The
22. CERTIFICATION LABEL
33. THE FIREPLACE3.1 INTRODUCTIONThe BIS ULTRA fireplace is an energy efficient, heat circulating, close combustionfireplace. You will
43.2 OPERATING THE BIS ULTRA3.2.1 FuelThe BIS ULTRA is designed to work best when fuelled with seasoned cordwood.Hardwoods are preferred t